ELECTRODE PADS 2X2 SQUARE FOAM BACKING - 10 PACKS OF 4
RHB1033FM40
• Continue pain-relieving treatments with FDA approved
replacement electrode pads.
• Pre-gelled with a conductive hydrogel, the pads easily
secure to the skin without leaving a sticky residue
following each treatment.
Features
SAFE REPLACEMENT PADS
Continue pain-relieving treatments with FDA approved replacement electrode pads
UNIVERSAL COMPATIBILITY
Pigtail 2mm stud or snap connector is compatible with most TENS, EMS, and muscle stimulation devices
PREGELLED AND SELF ADHESIVE
Pregelled with a conductive hydrogel, the pads easily secure to the skin without leaving a sticky residue following each treatment
FLEXIBLE SQUARE PADS
Square electrode pads are constructed with a non-woven cloth backing that is flexible for optimal placement
LATEX FREE
Latex-free and PVC-free, the non-irritating electrode pads are safe for all skin types
REUSABLE 10 SETS OF 4
Each set of four includes a protective liner in the resealable pouch for safe storage
Specifications
SPECIFICATIONS:
Uses:
Replacement electrode pads for TENS, EMS, and muscle stimulation devices
Dimensions:
1.97” by 1.97”
Materials:
Non-woven cloth backing
Conductive carbon film (Low impedance)
Conductive hydrogel
Lead wire with 2mm DIN size or snap connector
How To Use:
Read the device user manual thoroughly before use.
Skin must always be clean, dry and free from lotion or powders.
Attach lead wires to electrodes before applying to skin.
Remove the protective backing from the electrode. Save for future use.
Apply the electrode to the skin, center first, then smooth down the edges.
Attached are the lead wires to the device and turn it on. Adjust the settings according to the treatment plan. Do not exceed the intensity of .1 Watt/cm2.
When treatment is complete, turn the device off.
Lift the electrode at the edges and peel to remove it from the skin.
Care Instructions:
Replace the saved backing on the sticky side of the electrode.
Disconnect the device from the lead wires and electrode.
Store the electrode in the original packaging.
Keep electrodes away from direct sunlight.
If the electrode loses adhesion properties, gently rub one or two drops of water onto the gel surface to reactivate the adhesion. If that does not work, discard the electrode.
Discard the electrode in the original packaging after 20-25 uses.
What’s Included:
10 sets of 4 Replacement electrode pads with lead connectors
60 day guarantee
UPC: 818323021219
Product Number: RHB1033PIN
Shipping Weight: 11.2 ounces
User Manual: Lead Electrodes (2" x 2") - 10 Sets of 4